All systems
Technical sheet
A.01A.02
SystemS-45

Walkable flat roof / terrace

A walkable «inverted» flat roof: the insulation sits above the waterproofing, which stays protected, and the walking surface is made of stone or porcelain pavers laid on adjustable pedestals. Rainwater drops through the joints between the pavers, runs over the insulation and reaches the outlets following the fall of the screed below. It is the liveable terrace: inspectable, draining and well insulated.

CoperturaWalkable inverted flat roof, floating floor
B.01
System build-up6 layers
ESTERNOINTERNO1. Quadrotti2. Piedini3. XPS (rovescio)4. Guaina5. Massetto6. Solaio

Technical section of the system, from inside (left) to outside (right).

Walkable inverted flat roof, floating floor
Pendenza minima
1,5-2%
Spessore isolante XPS
8-16cm
Altezza piedini
2-30 (regolabile)cm
Tipo di copertura
rovescia (isolante sopra)
Carico di esercizio
≥ 4 (praticabile)kN/m²
Quadrotti
pietra / gres / cls
Descriptive memo

A walkable «inverted» flat roof: the insulation sits above the waterproofing, which stays protected, and the walking surface is made of stone or porcelain pavers laid on adjustable pedestals. Rainwater drops through the joints between the pavers, runs over the insulation and reaches the outlets following the fall of the screed below. It is the liveable terrace: inspectable, draining and well insulated.

A walkable flat roof is a terrace. It is built «inverted»: unlike the traditional roof, the insulation is laid above the waterproofing membrane instead of below, so the membrane is protected from sun, frost and foot traffic and lasts much longer.

The floating floor on pedestals

The walking surface is made of pavers (stone, porcelain, concrete) resting on adjustable pedestals. Between one paver and the next the water passes and falls into the space below the floor, where it runs freely to the outlets: the floor is «floating» and draining. The pedestals, adjustable in height, create a perfectly level surface even over the falls.

Falls, tightness and drainage

Under everything, a screed gives the fall (≈ 1.5-2%) to the outlets; on it the waterproofing membrane makes the seal, turned up at the edges and around the drains. The water runs at two levels — above the insulation and, above all, on the membrane — so the outlets and overflows must be sized and inspectable.

Walkability and maintenance

Being walkable, the structure and the floor must be checked for the service loads. The advantage of the floating floor is maintenance: the pavers are lifted to inspect the membrane and clean the cavity without demolition. At the edges, parapets and a high enough upstand of the membrane are needed.

Systems architecture

Why it works

Inverted roof · protected membrane
traditional: exposedinverted: protectedin the inverted roof the insulation shields the membrane from sun, frost and trafficthe membrane works cool and lasts far longer — and stays inspectable

In the traditional roof the membrane is on top, exposed to sun, frost and foot traffic: it ages, cracks and loses its seal. In the «inverted» roof the order is reversed: the insulation (XPS, which does not fear water) is laid over the membrane, protecting it from UV, thermal shock and impact. The membrane works cool and sheltered, and lasts far longer; the floating floor above, removable, also makes it inspectable. A little efficiency is traded — water runs over the insulation — for much greater durability.

Membrane life by exposure

Comparison · insulants
Inverted (protected)
longest
Under ballast / gravel
long
Exposed, ballasted
medium
Exposed, bare
short

Longer bar = the longer the membrane lasts. Shielding it from UV and temperature swings is what extends its life: the inverted roof, with insulation over the membrane, protects it best.

Nodal details

Critical junctions · sections
123456
D.01
Pedestal and floating floor

The pavers rest at their corners on an adjustable pedestal, with an open joint between them: rainwater drops straight through into the cavity below and runs over the insulation to the outlets. The pedestal head levels the floor and keeps the pavers off the insulation, so the surface stays dry and flat.

  1. Paver
  2. Adjustable pedestal
  3. Open joint (drains)
  4. XPS insulation
  5. Waterproofing
  6. Screed
123456
D.02
Edge and membrane upstand

At the parapet the waterproofing is turned up well above the finished floor — the upstand — and capped, so wind-driven water cannot get behind it. The pavers stop short of the wall, leaving a drainage margin; a coping protects the top of the parapet.

  1. Parapet
  2. Membrane upstand
  3. Coping / flashing
  4. Pavers (edge)
  5. XPS insulation
  6. Screed

Installation controls

Specification · checklist

01 · Structure & falls

Structure for service loads
Screed falls 1.5–2%
Outlets at low points

02 · Waterproofing

Membrane to the outlets
Upstands at edges / penetrations
Flood test before covering

03 · Insulation (inverted)

Water-resistant XPS
Boards staggered, tight
Filter / separation layer

04 · Floating floor

Pedestals levelled
Open joints for drainage
Edge restraint of pavers

05 · Edges & maintenance

Parapet upstand height
Inspection access
Outlets and overflows clear

Recurring defects

Diagnostics · site
Termo-igrometrica
Leaks through the waterproofing
CauseA puncture, a failed lap or a poorly detailed upstand lets water through the membrane into the structure below.
PreventionContinuous membrane, welded laps, upstands at edges and penetrations, a flood test before covering.
Termo-igrometrica
Ponding from poor falls
CauseToo little fall, or settlement of the screed, leaves water standing on the membrane: it stresses it and finds every weakness.
PreventionFalls of 1.5–2% to the outlets, outlets at the low points, a stable screed, overflows.
Meccanica
Wind uplift of the pavers
CauseAt corners and edges wind suction can lift loose pavers and the insulation under them, especially on tall or exposed buildings.
PreventionHeavier pavers or restraint at the edges, ballast to the wind zone, edge trims, a filter/ballast over the insulation.
Adesione
Blistering and detachment of the membrane
CauseMoisture trapped under a bonded membrane, or a dirty substrate, makes blisters that grow with heat and detach the sheet.
PreventionDry, primed substrate, the right bonding method, vapour control below, careful detailing at the laps.

Component materials